This version is the size of BTU
13,600 BTU/h , 18,000 BTU/h , 24,000 BTU/h , 30,000 BTU/h , 30,000 BTU/h , 36,000 BTU/h , 36,000 BTU/h , 42,000 BTU/h , 48,000 BTU/h
  • Energy saving with No.5 EGAT Label
  • Round flow 360 degrees
  • New airflow circulation
  • Up to 4.2 meter-high ceiling installation

Highlight Feature

  • Energy saving with No.5 EGAT Label

    Daikin's new round flow cassette inverter R32 has higher SEER value (energy-saving value). This Inverter is labelled with no.5 EGAT label, so this helps to save electricity much more.

  • Refrigerant R32

    R32 is an Eco-friendly refrigerant that is first used in Thailand by Daikin. Its cooling capability, known to be higher than R22 and R410A, decreases compressor’s overworking. As a result, air conditioners with R32 refrigerant can give faster cooling operation, save more energy consumption, and have 3 times less Global Warming Potential (GWP) than R410A. The total cumulative sales of split air conditioner with R32 refrigerant in Japan are over one million units.

  • Round flow 360 degrees

    Air flow thoroughly by round flow 360 degree louver. Cool steadily all over the area. Eliminate rough air flow problem, different from another 4 ways air conditioner.

  • New airflow circulation

    This new airflow circulation alternates airflow into 2 directions to distribute air through. As a result, it rapidly decreases the room's temperature and cool down the whole room. The users would feel too cold even though they are near the air conditioner.

  • Proper with up to 4.2 meter-high ceiling installation

    The value of air feeding can be adjusted to fit with 4.2 meter-high ceiling, so these cassettes can be installed in various areas. (model 36,000-48,000 BTU)

  • Filter and anti-bacteria drain tray

    Silver ion is used in the anti-bacteria drain tray to prevent the dispersion of bacteria that could lead to unpleasant odors and dirt.

Product specification

property
More information

Specification Unit FCFC13DV2S
Cooling CapacityBTU/h13,600 (6,100-15,400)
Power ConsumptionW1,220
Power SourceV/Ph/HzDV2S : 220V / 1 Phase / 50Hz
Indoor Unit Model   FCFC13DV2S
Front Panel Color Fresh White
Front Panel Size (HxWxD)mm50 x 950 x 950
Front Panel Weightkg5.5
Air Flow Rate H/M/Lcfm671 / 494 / 388
Fan Speed3 Steps
Air FilterResin net with mould resistance
Sound Level H/M/LdB(A)37 / 32 / 28
Dimension (HxWxD)mm256 x 840 x 840
Weightkg19
Outdoor Unit Model   RZFC13DV2S
Casing ColorIvory White
Sound Level Cooling/ Night Quiet ModedB(A)48 (Cooling)
Dimension (HxWxD)mm595 x 845 x 300
Weightkg34
Compressor Type Hermetically Sealed Swing Type
Refrigerant R32
Chargelessm10
Max. Interunit Piping Lengthm30
Max. Interunit Height Differencem15
Specification Unit FCFC18DV2S
Cooling CapacityBTU/h18,000 (7,800-20,500)
Power ConsumptionW1,630
Power SourceV/Ph/HzDV2S : 220V / 1 Phase / 50Hz
Indoor Unit Model   FCFC18DV2S
Front Panel Color Fresh White
Front Panel Size (HxWxD)mm50 x 950 x 950
Front Panel Weightkg5.5
Air Flow Rate H/M/Lcfm671 / 494 / 388
Fan Speed3 Steps
Air FilterResin net with mould resistance
Sound Level H/M/LdB(A)37 / 32 / 28
Dimension (HxWxD)mm256 x 840 x 840
Weightkg19
Outdoor Unit Model   RZFC18DV2S
Casing ColorIvory White
Sound Level Cooling/ Night Quiet ModedB(A)49 (Cooling)
Dimension (HxWxD)mm595 x 845 x 300
Weightkg34
Compressor Type Hermetically Sealed Swing Type
Refrigerant R32
Chargelessm10
Max. Interunit Piping Lengthm30
Max. Interunit Height Differencem15
Specification Unit FCFC24DV2S
Cooling CapacityBTU/h24,000 (8,900-27,300)
Power ConsumptionW2,150
Power SourceV/Ph/HzDV2S : 220V / 1 Phase / 50Hz
Indoor Unit Model   FCFC24DV2S
Front Panel Color Fresh White
Front Panel Size (HxWxD)mm50 x 950 x 950
Front Panel Weightkg5.5
Air Flow Rate H/M/Lcfm812 / 635 / 459
Fan Speed3 Steps
Air FilterResin net with mould resistance
Sound Level H/M/LdB(A)37 / 34 / 28
Dimension (HxWxD)mm256 x 840 x 840
Weightkg22
Outdoor Unit Model   RZFC24DV2S
Casing ColorIvory White
Sound Level Cooling/ Night Quiet ModedB(A)50 (Cooling)
Dimension (HxWxD)mm595 x 845 x 300
Weightkg37
Compressor Type Hermetically Sealed Swing Type
Refrigerant R32
Chargelessm10
Max. Interunit Piping Lengthm30
Max. Interunit Height Differencem15
Specification Unit FCFC30DV2S
Cooling CapacityBTU/h30,000 (14,300-34,100)
Power ConsumptionW2,830
Power SourceV/Ph/HzDV2S : 220V / 1 Phase / 50Hz / DY2S : 380V / 3 Phase / 50Hz
Indoor Unit Model   FCFC30DV2S
Front Panel Color Fresh White
Front Panel Size (HxWxD)mm50 x 950 x 950
Front Panel Weightkg5.5
Air Flow Rate H/M/Lcfm812 / 635 / 459
Fan Speed3 Steps
Air FilterResin net with mould resistance
Sound Level H/M/LdB(A)38 / 34 / 29
Dimension (HxWxD)mm256 x 840 x 840
Weightkg22
Outdoor Unit Model   RZFC30DV2S
Casing ColorIvory White
Sound Level Cooling/ Night Quiet ModedB(A)51 (Cooling)
Dimension (HxWxD)mm695 x 930 x 350
Weightkg44
Compressor Type Hermetically Sealed Swing Type
Refrigerant R32
Chargelessm15
Max. Interunit Piping Lengthm50
Max. Interunit Height Differencem30
Specification Unit FCFC30DV2S
Cooling CapacityBTU/h30,000 (14,300-34,100)
Power ConsumptionW2,830
Power SourceV/Ph/HzDY2S : 380V / 3 Phase / 50Hz
Indoor Unit Model   FCFC30DV2S
Front Panel Color Fresh White
Front Panel Size (HxWxD)mm50 x 950 x 950
Front Panel Weightkg5.5
Air Flow Rate H/M/Lcfm812 / 635 / 459
Fan Speed3 Steps
Air FilterResin net with mould resistance
Sound Level H/M/LdB(A)38 / 34 / 29
Dimension (HxWxD)mm256 x 840 x 840
Weightkg22
Outdoor Unit Model   RZFC30DY2S
Casing ColorIvory White
Sound Level Cooling/ Night Quiet ModedB(A)51 (Cooling)
Dimension (HxWxD)mm695 x 930 x 350
Weightkg46
Compressor Type Hermetically Sealed Swing Type
Refrigerant R32
Chargelessm15
Max. Interunit Piping Lengthm50
Max. Interunit Height Differencem30
Specification Unit FCFC36DV2S
Cooling CapacityBTU/h36,000 (17,100-38,200)
Power ConsumptionW3,420
Power SourceV/Ph/Hz"DV2S : 220V / 1 Phase / 50Hz "
Indoor Unit Model   FCFC36DV2S
Front Panel Color Fresh White
Front Panel Size (HxWxD)mm50 x 950 x 950
Front Panel Weightkg5.5
Air Flow Rate H/M/Lcfm1,200 / 953 / 706
Fan Speed3 Steps
Air FilterResin net with mould resistance
Sound Level H/M/LdB(A)45 / 38 / 33
Dimension (HxWxD)mm298 x 840 x 840
Weightkg24
Outdoor Unit Model   RZFC36DV2S
Casing ColorIvory White
Sound Level Cooling/ Night Quiet ModedB(A)52 (Cooling)
Dimension (HxWxD)mm695 x 930 x 350
Weightkg44
Compressor Type Hermetically Sealed Swing Type
Refrigerant R32
Chargelessm15
Max. Interunit Piping Lengthm50
Max. Interunit Height Differencem30
Specification Unit FCFC36DV2S
Cooling CapacityBTU/h36,000 (17,100 - 38,200)
Power ConsumptionW3,420
Power SourceV/Ph/HzDY2S : 380V / 3 Phase / 50Hz
Indoor Unit Model   FCFC36DV2S
Front Panel Color Fresh White
Front Panel Size (HxWxD)mm50 x 950 x 950
Front Panel Weightkg5.5
Air Flow Rate H/M/Lcfm1,200 / 953 / 706
Fan Speed3 Steps
Air FilterResin net with mould resistance
Sound Level H/M/LdB(A)45 / 38 / 33
Dimension (HxWxD)mm298 x 840 x 840
Weightkg24
Outdoor Unit Model   RZFC36DY2S
Casing ColorIvory White
Sound Level Cooling/ Night Quiet ModedB(A)52 (Cooling)
Dimension (HxWxD)mm695 x 930 x 350
Weightkg44
Compressor Type Hermetically Sealed Swing Type
Refrigerant R32
Chargelessm15
Max. Interunit Piping Lengthm50
Max. Interunit Height Differencem30
Specification Unit FCFC42DV2S
Cooling CapacityBTU/h42,000 (19,500-47,800)
Power ConsumptionW4,530
Power SourceV/Ph/HzDY2S : 380V / 3 Phase / 50Hz
Indoor Unit Model   FCFC42DV2S
Front Panel Color Fresh White
Front Panel Size (HxWxD)mm50 x 950 x 950
Front Panel Weightkg5.5
Air Flow Rate H/M/Lcfm1,271 / 1,024 / 741
Fan Speed3 Steps
Air FilterResin net with mould resistance
Sound Level H/M/LdB(A)46 / 40 / 33
Dimension (HxWxD)mm298 x 840 x 840
Weightkg24
Outdoor Unit Model   RZFC42DY2S
Casing ColorIvory White
Sound Level Cooling/ Night Quiet ModedB(A)54 (Cooling)
Dimension (HxWxD)mm990 x 940 x 320
Weightkg62
Compressor Type Hermetically Sealed Swing Type
Refrigerant R32
Chargelessm15
Max. Interunit Piping Lengthm50
Max. Interunit Height Differencem30
Specification Unit FCFC48DV2S
Cooling CapacityBTU/h48,000 (21,200-52,500)
Power ConsumptionW5,900
Power SourceV/Ph/HzDY2S : 380V / 3 Phase / 50Hz
Indoor Unit Model   FCFC48DV2S
Front Panel Color Fresh White
Front Panel Size (HxWxD)mm50 x 950 x 950
Front Panel Weightkg5.5
Air Flow Rate H/M/Lcfm1,271 / 1,024 / 741
Fan Speed3 Steps
Air FilterResin net with mould resistance
Sound Level H/M/LdB(A)46 / 40 / 33
Dimension (HxWxD)mm298 x 840 x 840
Weightkg24
Outdoor Unit Model   RZFC48DY2S
Casing ColorIvory White
Sound Level Cooling/ Night Quiet ModedB(A)56 (Cooling)
Dimension (HxWxD)mm990 x 940 x 320
Weightkg62
Compressor Type Hermetically Sealed Swing Type
Refrigerant R32
Chargelessm15
Max. Interunit Piping Lengthm30
Max. Interunit Height Differencem30
* Based on the 8 hour per day for a period of one year x electricity costs 3.96 baht per unit.
More Information

Use our Comfort System Calculator to figure out which system best fits your needs.

Product Features

MODELCassette FCFC-DV2S
Refrigerant and operation system 
R32 Refrigerant  
System   Swing Inverter Compressor
Cooling and airflow 
Auto airflow rate   (BRC2E61 Remote Control Only))
Health-friendly Technology 
Titanium apatite deoroizing filter  
Anri-bacteria drain pan  
Remote Control System 
Wireless remote control  
On/Off timer  
Wired Remote Control  
Convenience 
Auto vertical swing (up-down)  
Swing pattern selection   (BRC2E61 Remote Control Only)
High ceiling application   Can be used with wired remote
Two selectable temperature-sensor   Can be used with wired remote (model: BRC2E61)
Work and servicing 
Drain pump  
Filter sign  
Self-diagnosis display  
10-15 meters pipe run without adding refrigerants  
Filter worry-free  
Low-voltage Protection  
Emergency Mode  
Control features 
Auto-restart  
Control by 2 remote controllers  
Group control by 1 remote controller  
Central remote control  
Variety control design  
Control by other devices