Cassette FCF-CV2S - Daikin

Cassette FCF-CV2S

The no. 5 energy label ceiling mounted-360° round flow cassette controls the air direction evenly, the various patterns of air's release are selectable, so they can be installed in various space condition. With Swing Inverter compressor can save energy and provide stable cool temperature. R410A refrigerant provides high cooling capacity and does not deplete ozone layers. Minimum operation sound is only 27.5 decibels. Equipped with air filter and drain pan coated with anti-bacteria agent for user's health.

This version is the size of BTU
13,880 BTU/h , 18,090 BTU/h , 24,230 BTU/h , 30,090 BTU/h , 30,090 BTU/h , 36,230 BTU/h , 36,230 BTU/h , 42,000 BTU/h , 42,000 BTU/h , 48,000 BTU/h , 48,000 BTU/h
  • No.5 EGAT energy label with Swing Inverter compressor
  • 360° round flow cassette, rapid cooling throughout the room
  • New airflow distribution
  • Adjustable fan level up to 5 levels

Highlight Feature

  • No. 5 EGAT Label (energy-saving) in all models

    Daikin's new SkyAir R32 Inverter has higher SEER value (energy-saving value) than previous Inverters. This Inverter is granted with no.5 EGAT label, so this helps to save electricity much more.

  • Refrigerant R32

    R32 is an Eco-friendly refrigerant that is first used in Thailand by Daikin. Its cooling capability, known to be higher than R22 and R410A, decreases compressor’s overworking. As a result, air conditioners with R32 refrigerant can give faster cooling operation, save more energy consumption, and have 3 times less Global Warming Potential (GWP) than R410A. The total cumulative sales of split air conditioner with R32 refrigerant in Japan are over one million units.

  • Swing-inverter compressor

    Daikin’s Swing Inverter Compressor is outstanding from other Inverter compressors. The connected compressor core and roller effectively reduce friction and vibration, as well as refrigerant leak during compression. Compressor speed is highly increased as soon as it starts up giving fast cooling operation. As the temperature reaches the set limit, compressor speed will be reduced to stabilize the temperature. As a result, Swing Inverter compressors allow air conditioners to work quieter, reduce surges, and save more energy consumption that non-Inverter air conditioners.

  • Selectable multiple front panel's patterns

    You can select multiple front panels to fit with interior decoration and actual usages
    - white panel
    - black panel
    - white panel with sensor
    - black panel with sensor
    - premium panel
    - automatic grill (up-down)

  • New airflow circulation

    This new airflow circulation alternates airflow into 2 directions to distribute air through. As a result, it rapidly decreases the room's temperature and cool down the whole room. The users would feel too cold even though they are near the air conditioner.

  • Round flow 360 degrees

    Air flow thoroughly by round flow 360 degree louver. Cool steadily all over the area. Eliminate rough air flow problem, different from another 4 ways air conditioner.

  • Autonomous swing control

    The direction of air distribution can be adjusted freely so as to be suitable for distributing air in each corners of the room. Users can choose from 5 levels of positions and adjust the air direction.

  • Adjustable air distribution up to 5 levels

    The air distribution can be adjusted up to 5 levels with the automatic air distribution mode in order to reduce the room's temperature to reach the aimed value quickly.

  • Same sizes in all models make them easy to be installed

    The sizes of the shapes are equal in all models ranging from 13,880 to 48,000 BTU, so these cassettes look properly aligned when multiple of them are installed.

  • The degree of air discharged can be adjusted

    When the cassettes are delivered from the factory, the degree of air discharge is formerly set at the standard position. In fact, users can set anti-ceiling dirt value with the narrowest swing degree from the ceiling by changing from 15 degrees to 25 degrees.

  • Easily maintain, extend its useful life

    Verify a drain pan or waste water by unplug the air suction duct and ventilate panel. Air suction duct is transparent. Easy to see waste water which is conducted by drain pump mechanism. The pump can push waste water over the ceiling for 850 mm.

  • Compact design, easy setting and quiet operation

    Every model has light weight, can be set up without a hoist. Air suction panel can be changed into the same direction. Quiet operation, it is able to operate at the lowest sound label at 27.5 dB(A) level.

  • Filter and anti-bacteria drain tray

    Silver ion is used in the anti-bacteria drain tray to prevent the dispersion of bacteria that could lead to unpleasant odors and dirt.

  • Proper with up to 4.2 meter-high ceiling installation

    The value of air feeding can be adjusted to fit with 4.2 meter-high ceiling, so these cassettes can be installed in various areas.
    (model 30,000-48,000 BTU)

  • Installation-space saving

    Owning to the newly designed anti-corrosion alloy condenser in all models can help reduce the size of condensing up to 33% and the weight up to 51%. Consequently, these cassettes can be installed in the narrow spaces easily. The efficiency remains the same, cooling capacity and energy-saving capability become even higher.

  • Cost and installation time saving

    If users would like to change the internal air conditioners to Daikin's new skyair inverter, technicians can use the existing refrigerant R22 pipe without having to wash or replace with the new pipe. Therefore, it saves cost and installation time. (Users can check the sizes of pipes from the installation manual)

  • Accessories for special operation

    Special long-life air filter has long shelf-life even being installed in the massive dusty room with the long hour-used air conditioner. It is required to be cleaned only once a year.

Product specification

property
More information

Specification Unit FCF13CV2S
Cooling CapacityBTU/h13,880 (10,900-15,400)
Power ConsumptionW755
SEERBTU/W-h25.98
ฉลากประหยัดไฟเบอร์ห้า 
Power SourceV/Ph/Hz220 V / 1 Phase/ 50 Hz
Indoor Unit Model   FCF13CV2S
Front Panel Color Fresh White (ขาว)
Front Panel Size (HxWxD)mm50 x 950 x 950
Front Panel Weightkg5.5
Air Flow Rate H/M/Lcfm812 / 741 / 653 / 565 / 477
Fan Speed5 Steps
Air Direction ControlAuto Swing, 360 Degree
Air FilterResin net (with mould resistance)
Sound Level H/M/LdB(A)37 / 34.5 / 32 / 29.5 / 27.5
Dimension (HxWxD)mm256 x 840 x 840
Weightkg22
Outdoor Unit Model   RZF13CV2S
Casing ColorIvory White (สีขาวงาช้าง)
Air Flow Ratecfm1,589
Sound Level Cooling/ Night Quiet ModedB(A)48 / 44
Dimension (HxWxD)mm595 x 845 x 300
Weightkg41
Compressor Type Hermetically Sealed Swing Type
Refrigerant R32
Chargelessm30
Max. Interunit Piping Lengthm50 (Equivalent length 70 m)
Max. Interunit Height Differencem30
Specification Unit FCF18CV2S
Cooling CapacityBTU/h18,090 (10,900-20,500)
Power ConsumptionW1,095
SEERBTU/W-h25.28
ฉลากประหยัดไฟเบอร์ห้า 
Power SourceV/Ph/Hz220 V / 1 Phase/ 50 Hz
Indoor Unit Model   FCF18CV2S
Front Panel Color Fresh White (ขาว)
Front Panel Size (HxWxD)mm50 x 950 x 950
Front Panel Weightkg5.5
Air Flow Rate H/M/Lcfm812 / 741 / 653 / 565 / 477
Fan Speed5 Steps
Air Direction ControlAuto Swing, 360 Degree
Air FilterResin net (with mould resistance)
Sound Level H/M/LdB(A)37 / 34.5 / 32 / 29.5 / 27.5
Dimension (HxWxD)mm256 x 840 x 840
Weightkg22
Outdoor Unit Model   RZF18CV2S
Casing ColorIvory White (สีขาวงาช้าง)
Air Flow Ratecfm1,589
Sound Level Cooling/ Night Quiet ModedB(A)48 / 44
Dimension (HxWxD)mm595 x 845 x 300
Weightkg41
Compressor Type Hermetically Sealed Swing Type
Refrigerant R32
Chargelessm30
Max. Interunit Piping Lengthm50 (Equivalent length 70 m)
Max. Interunit Height Differencem30
Specification Unit FCF24CV2S
Cooling CapacityBTU/h24,230 (10,900-27,300)
Power ConsumptionW1,815
SEERBTU/W-h22.51
ฉลากประหยัดไฟเบอร์ห้า 
Power SourceV/Ph/Hz220 V / 1 Phase/ 50 Hz
Indoor Unit Model   FCF24CV2S
Front Panel Color Fresh White (ขาว)
Front Panel Size (HxWxD)mm50 x 950 x 950
Front Panel Weightkg5.5
Air Flow Rate H/M/Lcfm812 / 741 / 653 / 565 / 477
Fan Speed5 Steps
Air Direction ControlAuto Swing, 360 Degree
Air FilterResin net (with mould resistance)
Sound Level H/M/LdB(A)37 / 34.5 / 32 / 29.5 / 27.5
Dimension (HxWxD)mm256 x 840 x 840
Weightkg22
Outdoor Unit Model   RZF24CV2S
Casing ColorIvory White (สีขาวงาช้าง)
Air Flow Ratecfm1,589
Sound Level Cooling/ Night Quiet ModedB(A)48 / 44
Dimension (HxWxD)mm595 x 845 x 300
Weightkg41
Compressor Type Hermetically Sealed Swing Type
Refrigerant R32
Chargelessm30
Max. Interunit Piping Lengthm50 (Equivalent length 70 m)
Max. Interunit Height Differencem30
Specification Unit FCF30CV2S
Cooling CapacityBTU/h30,090 (17,100-34,100)
Power ConsumptionW2,450
SEERBTU/W-h20.82
ฉลากประหยัดไฟเบอร์ห้า 
Power SourceV/Ph/Hz220 V / 1 Phase/ 50 Hz
Indoor Unit Model   FCF30CV2S
Front Panel Color Fresh White (ขาว)
Front Panel Size (HxWxD)mm50 x 950 x 950
Front Panel Weightkg5.5
Air Flow Rate H/M/Lcfm1,218 / 1,094 / 971 / 847 / 706
Fan Speed5 Steps
Air Direction ControlAuto Swing, 360 Degree
Air FilterResin net (with mould resistance)
Sound Level H/M/LdB(A)45 / 41.5 / 38 / 35 / 32.5
Dimension (HxWxD)mm298 x 840 x 840
Weightkg24
Outdoor Unit Model   RZF30CV2S
Casing ColorIvory White (สีขาวงาช้าง)
Air Flow Ratecfm2,295
Sound Level Cooling/ Night Quiet ModedB(A)49 / 45
Dimension (HxWxD)mm695 x 930 x 350
Weightkg48
Compressor Type Hermetically Sealed Swing Type
Refrigerant R32
Chargelessm30
Max. Interunit Piping Lengthm50 (Equivalent length 70 m)
Max. Interunit Height Differencem30
Specification Unit FCF30CY2S
Cooling CapacityBTU/h30,090 (17,100-34,100)
Power ConsumptionW2,450
SEERBTU/W-h20.82
ฉลากประหยัดไฟเบอร์ห้า 
Power SourceV/Ph/Hz380 V / 3 Phase/ 50 Hz
Indoor Unit Model   FCF30CY2S
Front Panel Color Fresh White (ขาว)
Front Panel Size (HxWxD)mm50 x 950 x 950
Front Panel Weightkg5.5
Air Flow Rate H/M/Lcfm1,218 / 1,094 / 971 / 847 / 706
Fan Speed5 Steps
Air Direction ControlAuto Swing, 360 Degree
Air FilterResin net (with mould resistance)
Sound Level H/M/LdB(A)45 / 41.5 / 38 / 35 / 32.5
Dimension (HxWxD)mm298 x 840 x 840
Weightkg24
Outdoor Unit Model   RZF30CY2S
Casing ColorIvory White (สีขาวงาช้าง)
Air Flow Ratecfm2,295
Sound Level Cooling/ Night Quiet ModedB(A)49/45
Dimension (HxWxD)mm695 x 930 x 350
Weightkg48
Compressor Type Hermetically Sealed Swing Type
Refrigerant R32
Chargelessm30
Max. Interunit Piping Lengthm50 (Equivalent length 70 m)
Max. Interunit Height Differencem30
Specification Unit FCF36CV2S
Cooling CapacityBTU/h36,230 (17,100-38,200)
Power ConsumptionW3,250
SEERBTU/W-h19.5
ฉลากประหยัดไฟเบอร์ห้า 
Power SourceV/Ph/Hz220 V / 1 Phase/ 50 Hz
Indoor Unit Model   FCF36CV2S
Front Panel Color Fresh White (ขาว)
Front Panel Size (HxWxD)mm50 x 950 x 950
Front Panel Weightkg5.5
Air Flow Rate H/M/Lcfm1,218 / 1,094 / 971 / 847 / 706
Fan Speed5 Steps
Air Direction ControlAuto Swing, 360 Degree
Air FilterResin net (with mould resistance)
Sound Level H/M/LdB(A)45 / 41.5 / 38 / 35 / 32.5
Dimension (HxWxD)mm298 x 840 x 840
Weightkg24
Outdoor Unit Model   RZF36CV2S
Casing ColorIvory White (สีขาวงาช้าง)
Air Flow Ratecfm2,295
Sound Level Cooling/ Night Quiet ModedB(A)50 / 45
Dimension (HxWxD)mm695 x 930 x 350
Weightkg48
Compressor Type Hermetically Sealed Swing Type
Refrigerant R32
Chargelessm30
Max. Interunit Piping Lengthm50 (Equivalent length 70 m)
Max. Interunit Height Differencem30
Specification Unit FCF36CY2S
Cooling CapacityBTU/h36,230 (17,100-38,200)
Power ConsumptionW3,250
SEERBTU/W-h19.5
ฉลากประหยัดไฟเบอร์ห้า 
Power SourceV/Ph/Hz380 V / 3 Phase/ 50 Hz
Indoor Unit Model   FCF36CY2S
Front Panel Color Fresh White (ขาว)
Front Panel Size (HxWxD)mm50 x 950 x 950
Front Panel Weightkg5.5
Air Flow Rate H/M/Lcfm1,218 / 1,094 / 971 / 847 / 706
Fan Speed5 Steps
Air Direction ControlAuto Swing, 360 Degree
Air FilterResin net (with mould resistance)
Sound Level H/M/LdB(A)45 / 41.5 / 38 / 35 / 32.5
Dimension (HxWxD)mm298 x 840 x 840
Weightkg24
Outdoor Unit Model   RZF36CY2S
Casing ColorIvory White (สีขาวงาช้าง)
Air Flow Ratecfm2,295
Sound Level Cooling/ Night Quiet ModedB(A)50/45
Dimension (HxWxD)mm695 x 930 x 350
Weightkg48
Compressor Type Hermetically Sealed Swing Type
Refrigerant R32
Chargelessm30
Max. Interunit Piping Lengthm50 (Equivalent length 70 m)
Max. Interunit Height Differencem30
Specification Unit FCF42CV2S
Cooling CapacityBTU/h42,000 (19,500-47,800)
Power ConsumptionW4,155
SEERBTU/W-h16.58
Power SourceV/Ph/Hz220 V / 1 Phase/ 50 Hz
Indoor Unit Model   FCF42CV2S
Front Panel Color Fresh White (ขาว)
Front Panel Size (HxWxD)mm50 x 950 x 950
Front Panel Weightkg5.5
Air Flow Rate H/M/Lcfm1,288 / 1,165 / 1,024 / 883 / 741
Fan Speed5 Steps
Air Direction ControlAuto Swing, 360 Degree
Air FilterResin net (with mould resistance)
Sound Level H/M/LdB(A)46 / 43 / 40 / 36 / 32.5
Dimension (HxWxD)mm298 x 840 x 840
Weightkg24
Outdoor Unit Model   RZF42CV2S
Casing ColorIvory White (สีขาวงาช้าง)
Air Flow Ratecfm2,471
Sound Level Cooling/ Night Quiet ModedB(A)52 / 45
Dimension (HxWxD)mm990 x 940 x 320
Weightkg64
Compressor Type Hermetically Sealed Swing Type
Refrigerant R32
Chargelessm30
Max. Interunit Piping Lengthm50 (Equivalent length 70 m)
Max. Interunit Height Differencem30
Specification Unit FCF42CY2S
Cooling CapacityBTU/h42,000 (19,500-47,800)
Power ConsumptionW4,155
SEERBTU/W-h16.58
Power SourceV/Ph/Hz380 V / 3 Phase/ 50 Hz
Indoor Unit Model   FCF42CY2S
Front Panel Color Fresh White (ขาว)
Front Panel Size (HxWxD)mm50 x 950 x 950
Front Panel Weightkg5.5
Air Flow Rate H/M/Lcfm1,288 / 1,165 / 1,024 / 883 / 741
Fan Speed5 Steps
Air Direction ControlAuto Swing, 360 Degree
Air FilterResin net (with mould resistance)
Sound Level H/M/LdB(A)46 / 43 / 40 / 36 / 32.5
Dimension (HxWxD)mm298 x 840 x 840
Weightkg24
Outdoor Unit Model   RZF42CY2S
Casing ColorIvory White (สีขาวงาช้าง)
Air Flow Ratecfm2,471
Sound Level Cooling/ Night Quiet ModedB(A)52/45
Dimension (HxWxD)mm990 x 940 x 320
Weightkg64
Compressor Type Hermetically Sealed Swing Type
Refrigerant R32
Chargelessm30
Max. Interunit Piping Lengthm50 (Equivalent length 70 m)
Max. Interunit Height Differencem30
Specification Unit FCF48CV2S
Cooling CapacityBTU/h48,000 (21,200-52,500)
Power ConsumptionW5,444
SEERBTU/W-h15.55
Power SourceV/Ph/Hz220 V / 1 Phase/ 50 Hz
Indoor Unit Model   FCF48CV2S
Front Panel Color Fresh White (ขาว)
Front Panel Size (HxWxD)mm50 x 950 x 950
Front Panel Weightkg5.5
Air Flow Rate H/M/Lcfm1,288 / 1,165 / 1,024 / 883 / 741
Fan Speed5 Steps
Air Direction ControlAuto Swing, 360 Degree
Air FilterResin net (with mould resistance)
Sound Level H/M/LdB(A)46 / 43 / 40 / 36 / 32.5
Dimension (HxWxD)mm298 x 840 x 840
Weightkg24
Outdoor Unit Model   RZF48CV2S
Casing ColorIvory White (สีขาวงาช้าง)
Air Flow Ratecfm2,471
Sound Level Cooling/ Night Quiet ModedB(A)54 / 45
Dimension (HxWxD)mm990 x 940 x 320
Weightkg64
Compressor Type Hermetically Sealed Swing Type
Refrigerant R32
Chargelessm30
Max. Interunit Piping Lengthm50 (Equivalent length 70 m)
Max. Interunit Height Differencem30
Specification Unit FCF48CY2S
Cooling CapacityBTU/h48,000 (21,200-52,500)
Power ConsumptionW5,444
SEERBTU/W-h15.55
Power SourceV/Ph/Hz380 V / 3 Phase/ 50 Hz
Indoor Unit Model   FCF48CY2S
Front Panel Color Fresh White (ขาว)
Front Panel Size (HxWxD)mm50 x 950 x 950
Front Panel Weightkg5.5
Air Flow Rate H/M/Lcfm1,288 / 1,165 / 1,024 / 883 / 741
Fan Speed5 Steps
Air Direction ControlAuto Swing, 360 Degree
Air FilterResin net (with mould resistance)
Sound Level H/M/LdB(A)46 / 43 / 40 / 36 / 32.5
Dimension (HxWxD)mm298 x 840 x 840
Weightkg24
Outdoor Unit Model   RZF48CY2S
Casing ColorIvory White (สีขาวงาช้าง)
Air Flow Ratecfm2,471
Sound Level Cooling/ Night Quiet ModedB(A)54/45
Dimension (HxWxD)mm990 x 940 x 320
Weightkg64
Compressor Type Hermetically Sealed Swing Type
Refrigerant R32
Chargelessm30
Max. Interunit Piping Lengthm50 (Equivalent length 70 m)
Max. Interunit Height Differencem30
* Based on the 8 hour per day for a period of one year x electricity costs 3.96 baht per unit.
More Information

Use our Comfort System Calculator to figure out which system best fits your needs.

Product Features

MODELCassette FCF-CV2S
Refrigerant and operation system 
R32 Refrigerant  
System   Swing-inverter
Health-friendly Technology 
Titanium apatite deoroizing filter  
Anri-bacteria drain pan  
Timer 
Weekly schedule timer   When used with model : BRC1E63
Remote Control System 
Setpoint auto reset   When used with model : BRC1E63
Setpoint range set   When used with model : BRC1E63
On/Off timer   When used with model : BRC7M635F
Convenience 
Auto vertical swing (up-down)  
Swing pattern selection   Can be used with wired remote
Program "Dry"  
High ceiling application  
Two selectable temperature-sensor   Can be used with wired remote
Work and servicing 
Drain pump  
Filter sign  
Ceiling soiling prevention  
Self-diagnosis display  
Control features 
Auto-restart  
Control by 2 remote controllers  
Group control by 1 remote controller  
Central remote control